STATUS 10
UART line status.
Bit
Value
Meaning
7
128
Not used
6
64
Transmit Shift Register Empty
5
32
Transmit Holding Register Empty
4
16
Break Detect
3
8
Framing Error
2
4
Parity Error
1
2
Overrun Error
0
1
Data Ready